Message
FRBC.Instruction
Fields
abnormal_condition: boolean Mandatory
Indicates if this is an instruction during an abnormal condition.actuator_id: ID Mandatory
ID of the actuator this instruction belongs to.execution_time: string Mandatory
Indicates the moment the execution of the instruction shall start. When the specified execution time is in the past, execution must start as soon as possible.id: ID Mandatory
ID of the instruction. Must be unique in the scope of the Resource Manager, for at least the duration of the session between Resource Manager and CEM.message_id: ID Mandatory
ID of this messagemessage_type: string Mandatory
operation_mode: ID Mandatory
ID of the FRBC.OperationMode that should be activated.operation_mode_factor: float Mandatory
The number indicates the factor with which the FRBC.OperationMode should be configured. The factor should be greater than or equal to 0 and less or equal to 1.