Message
FRBC.Instruction
Fields
abnormal_condition
: boolean
Mandatory
Indicates if this is an instruction during an abnormal condition.actuator_id
: ID
Mandatory
ID of the actuator this instruction belongs to.execution_time
: string
Mandatory
Indicates the moment the execution of the instruction shall start. When the specified execution time is in the past, execution must start as soon as possible.id
: ID
Mandatory
ID of the instruction. Must be unique in the scope of the Resource Manager, for at least the duration of the session between Resource Manager and CEM.message_id
: ID
Mandatory
ID of this messagemessage_type
: string
Mandatory
operation_mode
: ID
Mandatory
ID of the FRBC.OperationMode
that should be activated.operation_mode_factor
: float
Mandatory
The number indicates the factor with which the FRBC.OperationMode
should be configured. The factor should be greater than or equal to 0 and less or equal to 1.