Object
FRBC.OperationMode
Fields
abnormal_condition_only: boolean Mandatory
Indicates if this FRBC.OperationMode may only be used during an abnormal conditiondiagnostic_label: string Optional
Human readable name/description of the FRBC.OperationMode. This element is only intended for diagnostic purposes and not for HMI applications.elements: FRBC.OperationModeElement[] Mandatory
List of FRBC.OperationModeElements, which describe the properties of this FRBC.OperationMode depending on the fill_level. The fill_level_ranges of the items in the Array must be contiguous.id: ID Mandatory
ID of the FRBC.OperationMode. Must be unique in the scope of the FRBC.ActuatorDescription in which it is used.