Object
FRBC.OperationMode
Fields
abnormal_condition_only
: boolean
Mandatory
Indicates if this FRBC.OperationMode
may only be used during an abnormal conditiondiagnostic_label
: string
Optional
Human readable name/description of the FRBC.OperationMode
. This element is only intended for diagnostic purposes and not for HMI applications.elements
: FRBC.OperationModeElement[]
Mandatory
List of FRBC.OperationModeElements
, which describe the properties of this FRBC.OperationMode
depending on the fill_level. The fill_level_ranges of the items in the Array must be contiguous.id
: ID
Mandatory
ID of the FRBC.OperationMode
. Must be unique in the scope of the FRBC.ActuatorDescription
in which it is used.