FRBC.UsageForecastElement
duration: Duration
Mandatory
Indicator for how long the given usage_rate is valid.
usage_rate_expected: float
Mandatory
The most likely value for the usage rate; the expected increase or decrease of the fill_level per second. A positive value indicates that the fill level will decrease due to usage.
usage_rate_lower_68PPR: float
Optional
The lower limit of the range with a 68 % probability that the usage rate is within that range. A positive value indicates that the fill level will decrease due to usage.
usage_rate_lower_95PPR: float
Optional
The lower limit of the range with a 95 % probability that the usage rate is within that range. A positive value indicates that the fill level will decrease due to usage.
usage_rate_lower_limit: float
Optional
The lower limit of the range with a 100 % probability that the usage rate is within that range. A positive value indicates that the fill level will decrease due to usage.
usage_rate_upper_68PPR: float
Optional
The upper limit of the range with a 68 % probability that the usage rate is within that range. A positive value indicates that the fill level will decrease due to usage.
usage_rate_upper_95PPR: float
Optional
The upper limit of the range with a 95 % probability that the usage rate is within that range. A positive value indicates that the fill level will decrease due to usage.
usage_rate_upper_limit: float
Optional
The upper limit of the range with a 100 % probability that the usage rate is within that range. A positive value indicates that the fill level will decrease due to usage.