Skip to main content

Object

OMBC.OperationMode

Fields

abnormal_condition_only: boolean
Mandatory

Indicates if this OMBC.OperationMode may only be used during an abnormal condition.

diagnostic_label: string
Optional

Human readable name/description of the OMBC.OperationMode. This element is only intended for diagnostic purposes and not for HMI applications.

id: ID
Mandatory

ID of the OBMC.OperationMode. Must be unique in the scope of the Resource Manager, for at least the duration of the session between Resource Manager and CEM.

power_ranges: PowerRange[]
Mandatory

The power produced or consumed by this operation mode. The start of each PowerRange is associated with an operation_mode_factor of 0, the end is associated with an operation_mode_factor of 1. In the array there must be at least one PowerRange, and at most one PowerRange per CommodityQuantity.

running_costs: NumberRange
Optional

Additional costs per second (e.g. wear, services) associated with this operation mode in the currency defined by the ResourceManagerDetails , excluding the commodity cost. The range is expressing uncertainty and is not linked to the operation_mode_factor.