Message
PEBC.Instruction
Fields
abnormal_condition
: boolean
Mandatory
Indicates if this is an instruction during an abnormal condition.execution_time
: string
Mandatory
Indicates the moment the execution of the instruction shall start. When the specified execution time is in the past, execution must start as soon as possible.id
: ID
Mandatory
Identifier of this PEBC.Instruction
. Must be unique in the scope of the Resource Manager, for at least the duration of the session between Resource Manager and CEM.message_id
: ID
Mandatory
ID of this messagemessage_type
: string
Mandatory
power_constraints_id
: ID
Mandatory
Identifier of the PEBC.PowerConstraints
this PEBC.Instruction
was based on.power_envelopes
: PEBC.PowerEnvelope[]
Mandatory
The PEBC.PowerEnvelope
(s) that should be followed by the Resource Manager. There shall be at least one PEBC.PowerEnvelope
, but at most one PEBC.PowerEnvelope
for each CommodityQuantity.