Message
PEBC.Instruction
Fields
abnormal_condition: boolean Mandatory
Indicates if this is an instruction during an abnormal condition.execution_time: string Mandatory
Indicates the moment the execution of the instruction shall start. When the specified execution time is in the past, execution must start as soon as possible.id: ID Mandatory
Identifier of this PEBC.Instruction. Must be unique in the scope of the Resource Manager, for at least the duration of the session between Resource Manager and CEM.message_id: ID Mandatory
ID of this messagemessage_type: string Mandatory
power_constraints_id: ID Mandatory
Identifier of the PEBC.PowerConstraints this PEBC.Instruction was based on.power_envelopes: PEBC.PowerEnvelope[] Mandatory
The PEBC.PowerEnvelope(s) that should be followed by the Resource Manager. There shall be at least one PEBC.PowerEnvelope, but at most one PEBC.PowerEnvelope for each CommodityQuantity.