Message
PEBC.PowerConstraints
Fields
allowed_limit_ranges: PEBC.AllowedLimitRange[] Mandatory
The actual constraints. There shall be at least one PEBC.AllowedLimitRange for the UPPER_LIMIT and at least one AllowedLimitRange for the LOWER_LIMIT. It is allowed to have multiple PEBC.AllowedLimitRange objects with identical CommodityQuantities and LimitTypes.consequence_type: PEBC.PowerEnvelopeConsequenceType Mandatory
Type of consequence of limiting powerid: ID Mandatory
Identifier of this PEBC.PowerConstraints. Must be unique in the scope of the Resource Manager, for at least the duration of the session between Resource Manager and CEM.message_id: ID Mandatory
ID of this messagemessage_type: string Mandatory
valid_from: string Mandatory
Moment this PEBC.PowerConstraints start to be validvalid_until: string Optional
Moment until this PEBC.PowerConstraints is valid. If valid_until is not present, there is no determined end time of this PEBC.PowerConstraints.