Skip to main content

Message

PEBC.PowerConstraints

Fields

allowed_limit_ranges: PEBC.AllowedLimitRange[]
Mandatory

The actual constraints. There shall be at least one PEBC.AllowedLimitRange for the UPPER_LIMIT and at least one AllowedLimitRange for the LOWER_LIMIT. It is allowed to have multiple PEBC.AllowedLimitRange objects with identical CommodityQuantities and LimitTypes.

consequence_type: PEBC.PowerEnvelopeConsequenceType
Mandatory

Type of consequence of limiting power

id: ID
Mandatory

Identifier of this PEBC.PowerConstraints. Must be unique in the scope of the Resource Manager, for at least the duration of the session between Resource Manager and CEM.

message_id: ID
Mandatory

ID of this message

message_type: string
Mandatory

valid_from: string
Mandatory

Moment this PEBC.PowerConstraints start to be valid

valid_until: string
Optional