Skip to main content

Message

PPBC.EndInterruptionInstruction

Fields

abnormal_condition: boolean
Mandatory

Indicates if this is an instruction during an abnormal condition

execution_time: string
Mandatory

Indicates the moment PPBC.PowerSequence interruption shall end. When the specified execution time is in the past, execution must start as soon as possible.

id: ID
Mandatory

ID of the Instruction. Must be unique in the scope of the Resource Manager, for at least the duration of the session between Resource Manager and CEM.

message_id: ID
Mandatory

ID of this message

message_type: string
Mandatory

power_profile_id: ID
Mandatory

ID of the PPBC.PowerProfileDefinition of which the PPBC.PowerSequence interruption is being ended by the CEM.

power_sequence_id: ID
Mandatory

ID of the PPBC.PowerSequence for which the CEM wants to end the interruption.

sequence_container_id: ID
Mandatory

ID of the PPBC.PowerSequnceContainer of which the PPBC.PowerSequence interruption is being ended by the CEM.