Object

Transition

Fields

abnormal_condition_only: boolean
Mandatory

Indicates if this Transition may only be used during an abnormal condition (see Clause )

blocking_timers: ID[]
Mandatory

List of IDs of Timers that block this Transition from initiating while at least one of these Timers is not yet finished

from: ID
Mandatory

ID of the OperationMode (exact type differs per ControlType) that should be switched from.

id: ID
Mandatory

ID of the Transition. Must be unique in the scope of the OMBC.SystemDescription, FRBC.ActuatorDescription or DDBC.ActuatorDescription in which it is used.

start_timers: ID[]
Mandatory

List of IDs of Timers that will be (re)started when this transition is initiated

to: ID
Mandatory

ID of the OperationMode (exact type differs per ControlType) that will be switched to.

transition_costs: float
Optional

Absolute costs for going through this Transition in the currency as described in the ResourceManagerDetails.

transition_duration: Duration
Optional

Indicates the time between the initiation of this Transition, and the time at which the device behaves according to the Operation Mode which is defined in the ‘to’ data element. When no value is provided it is assumed the transition duration is negligible.